In the NeoTec sensor world you will find the necessary products and accessories for the realization of technical measurement, control and regulation functions as well as for the associated sensory recording of the individual relevant parameters. This requires the use of high-precision sensors, which must be specially adapted to the application and the parameter to be measured. In the field of water treatment, sensors for measuring the relevant parameters are particularly useful:
- Conductivity
- pH value
- redox potential
- free oxygen turbidity
- UV transmission (monitoring UV systems)
- TOC value other application-specific chemical and physical parameters
On request, further sensors can be integrated on a customer-specific basis or are available in the Neomeris portfolio. You would like to integrate already existing sensors into the monitoring concept? Third-party sensor technology integrated in your process can be integrated by means of the signal converter modules.
Filter products
The Neomeris Chlorine Dioxide Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of three different ppm chlorine dioxide measurement ranges for your measurement. The basis here ist the amperometric measurement.Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5 or 0-10ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Chlorine Dioxide 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks. Frequently Asked Questions What does the electrode measure? You use this electrode to measure the pH value of liquids. This means you can determine whether a liquid is acidic, neutral, or alkaline. Is the electrode suitable for heavily contaminated water? Yes, it is specifically designed for dirty and challenging media such as wastewater or paints. This robust industrial electrode is engineered for the most demanding applications involving high levels of contamination and toxins, as well as oily media. Can I use it to measure high temperatures? Yes, it is suitable for applications up to 130°C and remains stable under these conditions. Does this electrode require a lot of maintenance? No, it features a robust design and requires minimal regular maintenance. Is the measurement reliable in the presence of oil or dirt? Yes, it delivers stable readings even in oily and heavily contaminated media. How long does the electrode last in industrial use? Its heavy-duty construction ensures a significantly extended service life.
The Neomeris Chlorine Dioxide Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of three different ppm chlorine dioxide measurement ranges for your measurement. The basis here ist the amperometric measurement.Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5 or 0-10ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Chlorine Dioxide 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
The Neomeris Chlorine Dioxide Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of three different ppm chlorine dioxide measurement ranges for your measurement. The basis here ist the amperometric measurement.Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5 or 0-10ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Chlorine Dioxide 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery: 1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP). Frequently Asked Questions Is this cable compatible with my pH or redox electrode? Yes, if your electrode has a rotatable cable connector (on the sensor side), you can use this connection cable without any issues. What is the unterminated cable end (without a plug) intended for? The open end is ideal if you wish to connect the cable directly to a measuring device or an existing terminal block. Why does the cable have a rotatable connector at the sensor end? The rotatable connector makes installation easier and prevents the cable from twisting during mounting. Can I extend or shorten the cable? The open end can be modified, shortened, or connected to a suitable plug as needed. Is the cable suitable for use in water or damp environments? Yes, it is designed for typical measurement environments associated with pH and redox monitoring. How do I correctly connect the cable to my electrode? Simply attach the rotatable connector to the electrode's connection point and tighten it securely. Is the cable suitable for continuous use? Yes, it is designed for the regular and continuous operation of pH or redox measurement systems. What should I do if I am unsure whether the cable fits? Simply send us the details of your electrode or measuring device—we will be happy to assist you.
Cooler consists of Titanium steel 1.4571 for automatic sampling to 120°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm Dimensions: 546 x 128 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler made of titanium stainless steel 1.4571 for the automatic extraction of water samples up to 200°C hot water. Technical data:Max. hot water pressure: 40 barMax. Cold water pressure: 8 barMax. Max. hot water temperature: 0-200°C Connections:Cooling water (inlet and outlet): ½ ”Hot water (inlet and outlet): 8 mm Dimensions:546 x 128 mm Weight:2.3 kg Length of the cooling coil:5.1 metri Material:Titanium stainless steel AISI316Ti4, EN 1.4571(Wall bracket: AISI316L, EN 1.4404) Performance (example for analyzers):< 40°C with cooling water at a temperature of <25°C at a water flow of the sample water of approx. 23 L/h Classification of the liquids: Class 2 - non-hazardous liquids Classification of the coolant Dir 2014/68 UE PED: Class A
Cooler consists of Titanium steel 1.4571 for automatic sampling to 80°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm Dimensions: 598 x 335 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for manual sampling to 120°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm Dimensions: 598 x 335 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for for manual sampling to 80°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: 8 mm Cold water outlet: ½ Hot water (in- and outlet): 8 mm Dimensions: 413 x 335 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Our flow cell kit is a simple and economical means of mounting pH and ORP electrodes for inline applications. Compatible with all 12 mm electrodes.
Our flow cell kit is a simple and economical means of mounting pH and ORP electrodes for inline applications. Compatible with all 12 mm electrodes.
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial and municipal, general water and waste water engineeringProcess measurements, electroplating, final inspections, neutralisation plantsdrinking and well water, boiler feed waterlightly contaminated waste waterDouble-chamber design in the presence of electrode poisons (e.g. sulphides, cyanides)low-temperature applications (-30 ... +30 °C), e.g. measurement in cooling systemsFluoride-containing (hydrofluoric acid) media up to 1000 mg/l HFHigh-alkali applications (reduced alkali error at pH values > pH 12)Special featuresHigh-quality zirconium dioxide diaphragm (glass fibre diaphragm with plastic shaft)Cartridge discharge system with silver ion-free reference electrolytepressure-resistant versions up to 10 bar (50 °C)Temperature range: up to -5 ... +80 °C (90 °C for ORP) or -30 ... +30 °C (with TT version)Temperature sensors can be integrated as an optionoptional salt reserve to increase the service life in media with lower conductivity or in drinking waterJUMO HA glass for continuous measurements in the range up to pH 14ORP versions with platinum or gold tip up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industry
Typical areas of applicationindustrial and municipal, general water and waste water engineeringProcess measurements, electroplating, final inspections, neutralisation plantsdrinking and well water, boiler feed waterlightly contaminated waste waterDouble-chamber design in the presence of electrode poisons (e.g. sulphides, cyanides)low-temperature applications (-30 ... +30 °C), e.g. measurement in cooling systemsFluoride-containing (hydrofluoric acid) media up to 1000 mg/l HFHigh-alkali applications (reduced alkali error at pH values > pH 12)Special featuresHigh-quality zirconium dioxide diaphragm (glass fibre diaphragm with plastic shaft)Cartridge discharge system with silver ion-free reference electrolytepressure-resistant versions up to 10 bar (50 °C)Temperature range: up to -5 ... +80 °C (90 °C for ORP) or -30 ... +30 °C (with TT version)Temperature sensors can be integrated as an optionoptional salt reserve to increase the service life in media with lower conductivity or in drinking waterJUMO HA glass for continuous measurements in the range up to pH 14ORP versions with platinum or gold tip up to ±2000 mV
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Maintenance kit for Neomeris Select chlorine dioxide sensorEnsure proper operation and high measurement accuracy with our chlorine dioxide sensor service kit and also extend the life of the sensor.Content:1x Replacement membrane cap1x Replacement pressure relief strap2x 30-mL bottles of electrolyte refill solution2x 10-mL syringes3x Polishing squares
Maintenance kit for Neomeris Select free chlorine sensorEnsure proper operation and high measurement accuracy with our free chlorine sensor service kit and also extend the life of the sensor.Content:1x Replacement membrane cap1x Replacement pressure relief strap2x 30-mL bottles of electrolyte refill solution2x 10-mL syringes3x Polishing squares