Filter products
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Version: Glass shaft UW glassPTFE- ring diaphragmScrew head Pg 13,5 (S8)120mmSalt reservoirType code (shown on the electrode as well):201020/51-18-04-22-120/837 ; Part Nr. 321035
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: Screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-12-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Extra codes: Salt reserve, with integrated Pt1000Order code: 201020/79-12-10-18/837, 841
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-18-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Type supplements: Salt reserve, with integrated Pt1000Order code: 201020/79-18-10/837, 841
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: platinum capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-07-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: gold capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-32-07-22-120/837
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivitySelected version:Basic type: Glass shaftActive part: Platinum capDiaphragm: PTFE ringElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-04-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, PEI plastic with protective cageActive part: Platinum domeDiaphragm: 1x glass fiberElectrical connection to electrode: screw head Pg13.5 (S8)Fitting length: 120mm (standard)Extra codes: Salt reserve, double chamber KCI/KCIOrder code: 201025/72-22-05-22-120/837, 838
Maintenance kit for Neomeris Select chlorine dioxide sensorEnsure proper operation and high measurement accuracy with our chlorine dioxide sensor service kit and also extend the life of the sensor.Content:1x Replacement membrane cap1x Replacement pressure relief strap2x 30-mL bottles of electrolyte refill solution2x 10-mL syringes3x Polishing squares
Maintenance kit for Neomeris Select free chlorine sensorEnsure proper operation and high measurement accuracy with our free chlorine sensor service kit and also extend the life of the sensor.Content:1x Replacement membrane cap1x Replacement pressure relief strap2x 30-mL bottles of electrolyte refill solution2x 10-mL syringes3x Polishing squares
Capacity measurement ion exchanger cartridgeOur Neomeris N-FLASH10 conductivity meter in a T-piece with 3/8 inch connection is a conductivity measuring instrument that is used to monitor the electrical conductivity of water after flowing through the ion exchanger cartridge. The measuring instrument including the integrated measuring cell is battery operated and permanently installed in the T-piece. If the measured electrical conductivity is below the limit value of 10µS/cm, the green LED flashes; if it is above, the red LED flashes, indicating that a cartridge or resin change is required. Due to the T-piece used, the measuring device can also be integrated very easily and is optimally installed in the liquid flow for a stable measurement. Measuring principle: The measuring cell generates an electrical signal that is proportional to the conductivity of the liquid. This signal is processed in the device and the LED is controlled via the programming stored in the device. Application: Conductivity meters are often used in water treatment plants in the process industry.Technical data:Screw-in thread: 3/8"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm