Conductivity
Conductivity Meters
Conductivity is a key parameter in water analysis, directly linked to the concentration of dissolved ions in water. It provides essential information about total mineralization, salinity, and water purity, making it highly relevant for drinking water monitoring, industrial process control, and reverse osmosis systems.
Typical Applications:
- Drinking water treatment and monitoring
- Industrial process and cooling water
- Laboratory quality control
- Reverse osmosis system monitoring
- Food and beverage production
Filter products
Device for the measurement of the electrical conductivity of aqueous solutions using a two-electrode conductivity cell without temperature compensation. Designed as measuring device with external measuring cell, with or without potential-free relay output available.- Applications: Demineralisation, reverse osmosis, desalination, cooling water recirc., phase separation- Operation at 9V DC via included wall transformer power supply.- Versions with relay output: 1 potential-free relay with reversible mode of action for the relay output- Optical limit indication via LEDs Technical Data- Measuring ranges: 0 - 10 / 100 / 1000 uS/cm, depending on type of device- Indication of limit values: Optical via LEDs, 2 limit values can be set within 0 and 100 % of the measuring range- Versions with relay output: 1 potential-free relay contact, max. 2 A / 250 V AC, 60 W / 62.5 VA- Versions with external measuring cell: For this reason measuring device includes wall brac
Device for the measurement of the electrical conductivity of aqueous solutions using a two-electrode conductivity cell without temperature compensation. Designed as measuring device with external measuring cell, with or without potential-free relay output available.- Applications: Demineralisation, reverse osmosis, desalination, cooling water recirc., phase separation- Operation at 9V DC via included wall transformer power supply.- Versions with relay output: 1 potential-free relay with reversible mode of action for the relay output- Optical limit indication via LEDs Technical Data- Measuring ranges: 0 - 10 / 100 / 1000 uS/cm, depending on type of device- Indication of limit values: Optical via LEDs, 2 limit values can be set within 0 and 100 % of the measuring range- Versions with relay output: 1 potential-free relay contact, max. 2 A / 250 V AC, 60 W / 62.5 VA- Versions with external measuring cell: For this reason measuring device includes wall brac
Device for the measurement of the electrical conductivity of aqueous solutions using a two-electrode conductivity cell without temperature compensation. Designed as measuring device with external measuring cell, with or without potential-free relay output available.- Applications: Demineralisation, reverse osmosis, desalination, cooling water recirc., phase separation- Operation at 9V DC via included wall transformer power supply.- Versions with relay output: 1 potential-free relay with reversible mode of action for the relay output- Optical limit indication via LEDs Technical Data- Measuring ranges: 0 - 10 / 100 / 1000 uS/cm, depending on type of device- Indication of limit values: Optical via LEDs, 2 limit values can be set within 0 and 100 % of the measuring range- Versions with relay output: 1 potential-free relay contact, max. 2 A / 250 V AC, 60 W / 62.5 VA- Versions with external measuring cell: For this reason measuring device includes wall brac
Device for the measurement of the electrical conductivity of aqueous solutions using a two-electrode conductivity cell without temperature compensation. Designed as measuring device with external measuring cell, with or without potential-free relay output available.- Applications: Demineralisation, reverse osmosis, desalination, cooling water recirc., phase separation- Operation at 9V DC via included wall transformer power supply.- Versions with relay output: 1 potential-free relay with reversible mode of action for the relay output- Optical limit indication via LEDs Technical Data- Measuring ranges: 0 - 10 / 100 / 1000 uS/cm, depending on type of device- Indication of limit values: Optical via LEDs, 2 limit values can be set within 0 and 100 % of the measuring range- Versions with relay output: 1 potential-free relay contact, max. 2 A / 250 V AC, 60 W / 62.5 VA- Versions with external measuring cell: For this reason measuring device includes wall brac
The Neomeris flush panel was developed for simple conductivity-controlled flushing processes in the cooling tower area. The control of the electric motor valve for the blowdown is carried out using a conductivity measuring cell of the type NeoTec Select. The flush panel is delivered pre-programmed and electrically wired ready for operation. The conductive conductivity measurement is pre-calibrated at the factory. The Neomeris Control DES control system has additional functions that can be used technically in consultation with Heyl Vertriebsgesellschaft if required.
The conductivity measuring package consists of a 3 meter connection cable, a 4-20mA head transmitter, and the conductivity sensor. Due to the design of the sensor assembly, only the sensor needs to be replaced, when it should be worn out . All other components of this system can be used continuously. For an optimal process integration the NeoTec sensor is delivered with a fitting T-piece. Advantages: preconfigured for NeoTecMaster® modular design industry standard resource friendly
The conductivity measuring package consists of a 3 meter connection cable, a 4-20mA head transmitter, and the conductivity sensor. Due to the design of the sensor assembly, only the sensor needs to be replaced, when it should be worn out . All other components of this system can be used continuously. For an optimal process integration the NeoTec sensor is delivered with a fitting T-piece. Advantages: preconfigured for NeoTecMaster® modular design industry standard resource friendly
The conductivity measuring package consists of a 3 meter connection cable, a Modbus head transmitter, and the conductivity sensor. Due to the design of the sensor assembly, only the sensor needs to be replaced, when it should be worn out . All other components of this system can be used continuously. For an optimal process integration the NeoTec sensor is delivered with a fitting T-piece. Advantages: preconfigured for NeoTecMaster® modular design industry standard resource friendly
The conductivity sensor consists of a 3 meter connection cable, a Modbus head transmitter, and the conductivity sensor. Due to the design of the sensor assembly, only the sensor needs to be replaced. All other components of this system can be used continuously. For an optimal process integration the NeoTec sensor is delivered with a fitting T-piece. Advantages:Preconfigured for NeoTecMaster® Modular design Industry standard conserves resources