The NeoTecMaster, as a multi-parameter system open to any manufacturer, enables you to monitor your water treatment plant, regardless of your location.
The multicontroller allows customer-specific extensions, e.g. connection to the cell phone network via GSM. In this category you will find all products necessary for your specific application and configuration of your NeoTecMaster. The technical selection options can be summarized as follows:
- Available as 1 to 8 -channel system
- Modular concept for signal inputs (Modbus-RTU, 4-20mA or RS232)
- Software architecture for the integration of Heyl Testomat instruments, such as Testomat EVO, Testomat 2000, Testomat LAB and Testomat 808 / 808 SIO2
- Possibility of integrating the entire NeoTec Neomeris Select sensors
- Integration of non-proprietary measurement technology
- Ethernet interface for network integration Visualization of status messages and measured values via web interface
Filter products
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Our Neomeris Select high temperature conductivity cells are suitable in a wide range of high performance applications with high temperatures and pressures.To meet these demanding technical requirements, our sensors are manufactured from 316 stainless steel with PEEK elements and feature a one-piece cell design suitable for high pressure conditions. The conductivity cells are available with different cell constants (0.1/cm and 1.0/cm) and temperature sensors (PT100 and PT1000) and are designed for a specific pressure-temperature range. Certain model types also allow you to choose between a short and long thread, depending on the installation situation.Our 1/2" inch Select LF stainless steel conductivity cell is a general purpose sensor that can be used in a variety of standard applications such as in cooling towers or water treatment plants, etc. and is easy to install. In contrast, our Select HTLF Ultra high performance conductivity cell is the top of the range model. This conductivity sensor is specially designed for boiler applications where it is permanently integrated in the boiler. Via our selection menu you can easily choose the right conductivity sensor for your application. Please contact us if you have any questions.
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 2.000.000 μS (0 - 2 S)
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 500.000 μS (0 - 500 mS)
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 2.000.000 μS (0 - 2 S)
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 2.000.000 μS (0 - 2 S)
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems. In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808 Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are the proven functionalities of the Testomat® 808: Indication of limit value undershoot or overshoot: green / red LED Modern indicator pump system Automatic measuring sequence with low water consumption Direct error and indicator quantity display Internal and external flushing of the measuring chamber by manual control Control of an external flush valve Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processing Safety check for 72-hour operation without supervision Indicator quantities: 100 and 500 ml bottles 4 - 20 mA interface for defined status and error messages RS 232 interface for firmware updates General information Water connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory)) Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter Water outlet: hose with 6 mm outer diameter/4 mm inner diameter Water temperature: 10 to 40 °C From 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808! Optional accessories: NeoTecMaster unit hood
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified. It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® functionalities of both devices: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® EVO TH: High-precision titration by means of piston metering pump LCD graphic display Multilingual menu with easy switching (internal programming is retained) External clear / acknowledge input Free programmable password Range monitoring (fall below limit value1 / exceed limit value 2) Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure) Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 100 and 500 ml bottles Analysis trigger: automatic interval operation (0-99 minutes) depending on quantity via contact water meter Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portoguese Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover
The Testomat® LAB CL is a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB CL in combination with the NeoTecMaster® Multi Channel Controller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input, in this case the RS232 interface, is used by the Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. Two modules that fundamentally expand the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA output module. This allows you to add potential-free relay contacts to the overall system and to realise linear or inverted dosing processes via the 4x 4-20mA output module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, also implement simple limit value-related control concepts, as well as output measurement value-related messages. Via the 4-20mA output module, you can also forward the measured values to a higher-level controller as desired. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portuguese Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover
The Testomat® LAB Monochloramine (NH2CL) is an online analyser that photometrically measures the content of monochloramine in process water and is used for continuous monitoring of process quality, for example in cooling circuits. Another area of application is the use in the environment of water treatment and drinking water plants, for process monitoring, as well as monitoring the decay behaviour in cooling towers after shock chlorination. The measuring range for monochloramine (NH2CL, calculated as Cl2) is 0 to 5 ppm (resolution 0.1). The instrument works according to the DPD method based on EN ISO 7393-2 and the analysis is carried out by adding two reagents. After a reaction time of approx. 60 seconds (dosing and measuring time without rinsing time) the measuring result is available. For the transmission of the measured values, in addition to the 4-20mA signal output, an RS232 interface is available for the transmission of the measured values as well as error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format and can be used for detailed observations at any time. In view of the fact that the Testomat® LAB Monochloramine was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB Monochloramine in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals in this version. One signal input on the NeoTecMaster®, in this case the RS232 interface, is used by Testomat® LAB Monochloramine to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA output module. This allows you to add potential-free relay contacts to the overall system and to realise linear or inverted dosing processes via the 4x 4-20mA output module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, also implement simple limit value-related control concepts, as well as output measurement value-related messages. Via the 4-20mA output module, you can also forward the measured values to a higher-level controller as desired. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in connection with the Testomat® LAB Monochloramine Integration into the existing control cabinet, alternatively we offer you our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® LAB Monochloramine: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of monochloramine (NH2CL) Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water and the Testomat® LAB CL is a robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB TH and Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you both Testomat® LAB analysis devices in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® LAB TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch; Portuguese Integrated self-test with continuous monitoring Automatic venting of the indicator line Compact design Performance profil Testomat® LAB TH: High-precision titration by means of piston metering pump Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 500 ml bottles Analysis trigger: - Automatic interval operation (interval pause adjustable from 0-255 minutes) - External analysis input (start/stop) - Manual start Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly. Analysis trigger: Automatic interval operation (interval pause adjustable from 0-255 minutes) External analysis input (start/stop) Manual start Optional accessories available: OLED display Protective cover to increase the IP protection class of the Testomat® LAB devices NeoTecMaster instrument cover
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water. In view of the fact that the Testomat® LAB TH was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB TH in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster®, in this case the RS232 interface, is used by Testomat® LAB TH to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB TH Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB TH functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portoguese Integrated self-test with continuous monitoring Automatic venting of the indicator line Compact design Proven performance profil: High-precision titration by means of piston metering pump Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 500 ml bottles Analysis trigger: - Automatic interval operation (interval pause adjustable from 0-255 minutes) - External analysis input (start/stop) - Manual start Optional accessories available: OLED display Protective cover to increase the IP protection class of the Testomat® LAB TH NeoTecMaster instrument cover
Features of the ARAD Sonata Ultrasonic Water Meter Precise ultrasonic water meter with 2 configurable pulse outputs The ARAD Sonata is a highly accurate ultrasonic water meter for reliable measurement of water consumption, nominal size DN 20 (3/4 inch). Its modern ultrasonic technology without moving parts ensures highly precise and wear-free measurement. The two configurable pulse outputs allow forward or reverse measurement. The pulse outputs can be flexibly integrated into existing reading, control, or monitoring systems. Forward, reverse, or combined measurements are possible, adapted to the desired resolution. Accurate Consumption Measurement with Modern Ultrasonic Technology The ARAD Sonata reliably measures water consumption even at very low flow rates. The ultrasonic technology operates completely without mechanical components, ensuring long-term accuracy and minimizing maintenance. This design makes the water meter particularly durable, robust, and suitable for long-term use. Flexible Pulse Outputs for Versatile Applications The two independent pulse outputs can be configured flexibly and support both forward and reverse measurements, allowing the meter to be optimally adapted to various billing, recording, or monitoring systems. The combination of high measurement precision, robust technology, and flexible signal processing makes the ARAD Sonata a reliable solution for modern water consumption monitoring.
Features of the ARAD Sonata Ultrasonic Water Meter Precise ultrasonic water meter with 2 configurable pulse outputs The ARAD Sonata is a highly accurate ultrasonic water meter for reliable measurement of water consumption, nominal size DN 20 (3/4 inch). Its modern ultrasonic technology without moving parts ensures highly precise and wear-free measurement. The two configurable pulse outputs allow forward or reverse measurement. The pulse outputs can be flexibly integrated into existing reading, control, or monitoring systems. Forward, reverse, or combined measurements are possible, adapted to the desired resolution. Accurate Consumption Measurement with Modern Ultrasonic Technology The ARAD Sonata reliably measures water consumption even at very low flow rates. The ultrasonic technology operates completely without mechanical components, ensuring long-term accuracy and minimizing maintenance. This design makes the water meter particularly durable, robust, and suitable for long-term use. Flexible Pulse Outputs for Versatile Applications The two independent pulse outputs can be configured flexibly and support both forward and reverse measurements, allowing the meter to be optimally adapted to various billing, recording, or monitoring systems. The combination of high measurement precision, robust technology, and flexible signal processing makes the ARAD Sonata a reliable solution for modern water consumption monitoring.