Filter products
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: Screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-12-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Extra codes: Salt reserve, with integrated Pt1000Order code: 201020/79-12-10-18/837, 841
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-18-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Type supplements: Salt reserve, with integrated Pt1000Order code: 201020/79-18-10/837, 841
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
The calibration box is used for the calibration of Modbus sensors. The wires from the sensors are connected to the terminal block on the front of the box and the Box is connected to a computer via a USB interface.Advantages:Simple and safe calibration of the Modbus sensors
The modular pH measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the flat-head pH electrode. Due to the design of the sensor assembly, only the pH electrode needs to be replaced. All other components of this system can be used continuously. For optimal process integration, the NeoTec Sensor is supplied with a suitable T-piece.Advantages:preconfigured for NeoTecMaster® modular design industry standard resource friendly
The modular pH measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the flat-head pH electrode. Due to the design of the sensor assembly, only the pH electrode needs to be replaced. All other components of this system can be used continuously. For optimal process integration, the NeoTec Sensor is supplied with a suitable T-piece.Advantages:preconfigured for NeoTecMaster® modular design industry standard resource friendly
A pH sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with Modbus modul encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with Modbus modul encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe