Filter products
Our flow cell kit is a simple and economical means of mounting pH and ORP electrodes for inline applications. Compatible with all 12 mm electrodes.
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: platinum capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-07-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: gold capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-32-07-22-120/837
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivitySelected version:Basic type: Glass shaftActive part: Platinum capDiaphragm: PTFE ringElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-04-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, PEI plastic with protective cageActive part: Platinum domeDiaphragm: 1x glass fiberElectrical connection to electrode: screw head Pg13.5 (S8)Fitting length: 120mm (standard)Extra codes: Salt reserve, double chamber KCI/KCIOrder code: 201025/72-22-05-22-120/837, 838
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
The calibration box is used for the calibration of Modbus sensors. The wires from the sensors are connected to the terminal block on the front of the box and the Box is connected to a computer via a USB interface.Advantages:Simple and safe calibration of the Modbus sensors
The modular ORP measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the ORP flat-head electrode. Due to the construction of the sensor only the ORP electrode has to be replaced. All other components of this system can be used continuously. For an optimal process integration the NeoTec Sensor is delivered with a fitting T-piece. Advantages:preconfigured for NeoTecMaster® modular design industry standard resource friendly
The modular ORP measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the ORP flat-head electrode. Due to the construction of the sensor only the ORP electrode has to be replaced. All other components of this system can be used continuously. For an optimal process integration the NeoTec Sensor is delivered with a fitting T-piece. Advantages:preconfigured for NeoTecMaster® modular design industry standard resource friendly
A ORP sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A ORP sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe