Filter products
Our flow cell kit is a simple and economical means of mounting pH and ORP electrodes for inline applications. Compatible with all 12 mm electrodes.
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: platinum capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-07-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: gold capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-32-07-22-120/837
If you are looking for a redox electrode designed for challenging media, robust process conditions, and a durable long-life configuration, this JUMO tecLine version is an excellent choice. JUMO tecLine redox electrode with glass shaft, platinum tip, PTFE ring, Pg13.5 screw head (S8), 120 mm and salt reservoir This redox electrode is designed for demanding redox measurements in water and aqueous media. It is particularly suitable for applications where the sensor must operate reliably under more difficult process conditions. The combination of glass shaft, platinum tip, PTFE ring diaphragm, Pg13.5 screw head (S8), 120 mm immersion length, and salt reservoir makes this version suitable for professional use in contaminated media and significantly more robust than basic standard solutions. Technical data Basic type: glass shaft Active element: platinum tip Redox measuring range: ±2000 mV Temperature range: -5 to +90 °C Diaphragm: PTFE ring Electrical connection: Pg13.5 screw head (S8) Reference system: cartridge reference system Immersion length: 120 mm Type extension: salt reservoir Advantages and special features A key advantage of this version is its suitability for media containing dirt, solid particles, or oil-based components that can interfere with measurement. The PTFE ring diaphragm is specifically designed for such demanding conditions and offers advantages over more sensitive standard diaphragm designs. This makes the electrode particularly attractive for users who require a reliable and durable redox measurement solution in industrial environments. Why choose this electrode? This version is especially suitable when the measuring point must remain reliable even in difficult media conditions. The platinum tip is designed for redox measurements up to ±2000 mV and is suitable for a wide range of industrial applications. The glass shaft provides a proven and process-suitable design, while the salt reservoir can help extend service life in low-conductivity media. This is particularly beneficial in applications where frequent maintenance or replacement is not desirable. The Pg13.5 screw head (S8) ensures compatibility with many standard measurement systems. With a 120 mm immersion length, the electrode fits into a wide range of common installation situations. Combined with the cartridge reference system, this results in a well-designed solution for processes requiring robust redox measurement and reliable long-term operation. Typical applications industrial wastewater treatment general process monitoring electroplating industry paper industry beverage industry oily wastewater, suspensions, paints, and media with solid particles fluoride-containing media up to 1000 mg/l HF
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, PEI plastic with protective cageActive part: Platinum domeDiaphragm: 1x glass fiberElectrical connection to electrode: screw head Pg13.5 (S8)Fitting length: 120mm (standard)Extra codes: Salt reserve, double chamber KCI/KCIOrder code: 201025/72-22-05-22-120/837, 838
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
The calibration box is used for the calibration of Modbus sensors. The wires from the sensors are connected to the terminal block on the front of the box and the Box is connected to a computer via a USB interface.Advantages:Simple and safe calibration of the Modbus sensors
The modular ORP measuring package consists of a 3 m connection cable, a Modbus head transmitter, the sensor holder and the ORP flat-head electrode. Due to the construction of the sensor only the ORP electrode has to be replaced. All other components of this system can be used continuously. For an optimal process integration the NeoTec Sensor is delivered with a fitting T-piece. Advantages:preconfigured for NeoTecMaster® modular design industry standard resource friendly
A ORP sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A ORP sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe