Measuring instruments by parameter
Filter products
The flow regulator DN 15, 1/2" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 25, 1" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 40, 1 1/2 " is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 50, 2" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 65, 2 1/2" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 80, 3" is suitable for the NEOMERIS Softmaster RS.
The instrument is used for conductive measurement / control of the electrolytic conductivity, the resistivity or the TDS value. In addition, the JUMO AQUIS 500 CR offers the possibility of displaying the measured conductivity according to a customer-specific table. display.Both conductive two-electrode and four-electrode measuring cells can be connected to the device. The temperature measurement is carried out as a second input variable with a Pt100/1000. Depending on the measured variable, specific automatic temperature compensation is possible.The unit is operated via keys and a large LC graphic display. This display makes it easy to read the measured value. The display of the parameters in plain text simplifies configuration for the operator and supports correct programming of the unit.The modular design of the unit allows it to be adapted to the requirements of the application. Up to four outputs are available.Typical areas of application:Universally applicable in water and wastewater management, service water, process water and wastewater, drinking, well and surface water, pure and ultrapure water applications, pharmaceutical water applications (e.g. according to USP, Ph.Eur., WFI), water quality measurements, TDS measurements (ppm or mg/l).Special features Direct switching option to specific - specific conductivity (µS/cm or mS/cm) - specific resistance (kΩ x cm or MΩ x cm) - TDS measurement (ppm or mg/l) - customer-specific tableAutomatic temperature compensation: off (e.g. USP), linear, ASTM, natural waters (EN 27888/ISO 7888)Large LC graphic display with backlightingDisplay presentation selectable: large digits, bargraph or tendency displayCalibration options depending on measured variable: cell constant and temperature coefficientCalibration logbookConnection possibility of two-electrode measuring cells (standard) or four-electrode measuring cellsActivatable contamination detection Autorange operation Protection class IP67 for surface mounting Protection class IP65 for control cabinet mountingOperator languages switchable: German, English, French; other languages via setup program RechargeableThrough setup program: convenient programming, system documentation, Loading of further operator languages JUMO Controllers – Precise Control for Various Processes JUMO controllers, especially from the modular AQUIS 500 series, provide reliable and flexible solutions for automated process control in water treatment, industry, and environmental technology. They are available for various measurement parameters such as temperature, pH, redox, conductivity, and oxygen, offering easy operation and high accuracy. At HeylNeomeris, you’ll find compact and modular JUMO controllers from the AQUIS 500 series, known for their robust design, multiple interface options, and flexible configuration possibilities. Why choose JUMO controllers: • Precise process control for optimal results • Durable and reliable even in demanding conditions • Easy integration into existing systems thanks to multiple interfaces • User-friendly menus and extensive configuration options Frequently Asked Questions What can I actually use the JUMO AQUIS 500 CR for? The transmitter measures conductivity, TDS, resistance and temperature in liquids, e.g. in water treatment, industrial plants or laboratory applications. Can I monitor several parameters simultaneously with the device? Yes, the AQUIS 500 CR can measure and display several parameters, such as conductivity and temperature, simultaneously. Is the device easy to install? Yes, the device is mounted in a surface-mounted housing and can be integrated into existing systems. Is the device suitable for industrial environments? Yes, the AQUIS 500 CR has been specially developed for use in industrial and process plants. Can I transmit the measured values to a control system? Yes, the analogue outputs allow measurement values to be easily transmitted to external control or monitoring systems. Does the device require frequent maintenance or calibration? Generally, occasional checks and calibration are sufficient, depending on the application and operating conditions. For which liquids is the device particularly well suited? Typical applications include water, process water or other conductive liquids in industry and engineering.
Version 2: stock version: type 202560/20-888-000-310-000-23/000 ; part-no. 00480050 The unit is used for measuring/controlling the pH-value, the redox-voltage or the NH3-(ammonia)-concentration. The function can be switched directly on the unit. Depending on the measurand, combination electrodes (e.g. pH/redox combination electrodes, gas-sensitive sensors) or separate versions (glass/metal electrodes with separate reference electrode) can be connected. The second input variable is the temperature measurement, which can be carried out with a Pt 100/1000, for example. Automatic temperature compensation is thus possible for the measured variables pH value and NH3. The units are operated via clear keys and a large LC graphic display. This display enables good readability of the measured value. The display of the parameters in plain text makes configuration easier for the operator and supports correct programming of the unit. The modular design of the unit allows it to be adapted to the requirements of the application. Up to four outputs are available. Special features direct switching option for pH value, redox voltage or NH3 (ammonia) concentration Automatic temperature compensation Large LC graphic display with backlighting Display selectable: large digits, bar graph or tendency display Solderless connection technology - Calibration options depending on measurand one/two/three-point calibration calibration logbook Impedance measurement can be activated for pH measurement Asymmetrical and symmetrical connection of pH sensors Possibility of connecting pH ISFET sensors through integrated output for sensor power supply Protection class IP67 for surface mounting, protection class IP65 for control cabinet mounting User languages switchable German, English, French; further languages can be loaded via setup program Through setup program: convenient programming, system documentation, reloading of further user languages JUMO AQUIS 500 – Modular Measuring and Control Systems for Precise Water Analysis The JUMO AQUIS 500 series includes a range of powerful, modular measuring and control devices for monitoring analytical water parameters such as pH, redox, conductivity, temperature, and more. Each model (e.g., AQUIS 500 pH, CR) is tailored to a specific sensor type or measurement range, making the series ideal for use in water treatment, environmental technology, process engineering, and industrial process monitoring. At HeylNeomeris, the AQUIS 500 series provides reliable solutions for stationary applications that demand high measurement accuracy, flexible system integration, and user-friendly operation. Advantages of the JUMO AQUIS 500 Series: • The series offers tailored solutions for various measurement tasks – from pH to conductivity • Modular design and compatibility allow for easy integration into existing systems • Digital interfaces (e.g., 0/4–20 mA, relay outputs) enable seamless automation • The devices deliver stable and precise measurements, even during continuous operation • A clear display and intuitive menu navigation simplify installation and maintenance • With IP65 protection and a robust design, they are well suited for industrial environments Frequently Asked Questions What can I actually use the JUMO AQUIS 500 CR for? The transmitter measures conductivity, TDS, resistance and temperature in liquids, e.g. in water treatment, industrial plants or laboratory applications. Can I monitor several parameters simultaneously with the device? Yes, the AQUIS 500 CR can measure and display several parameters, such as conductivity and temperature, simultaneously. Is the device easy to install? Yes, the device is mounted in a surface-mounted housing and can be integrated into existing systems. Is the device suitable for industrial environments? Yes, the AQUIS 500 CR has been specially developed for use in industrial and process plants. Can I transmit the measured values to a control system? Yes, the analogue outputs allow measurement values to be easily transmitted to external control or monitoring systems. Does the device require frequent maintenance or calibration? Generally, occasional checks and calibration are sufficient, depending on the application and operating conditions. For which liquids is the device particularly well suited? Typical applications include water, process water or other conductive liquids in industry and engineering.
Indicator/controller for digital sensors with Modbus protocolThe unit has 1 digital interface, 1 analogue temperature input and 1 binary input. The digital interface is suitable for connecting sensors that have a Modbus RS485 interface. If the connected sensor does not have an integrated temperature sensor, a resistance thermometer Pt100, Pt1000 or NTC/PTC (up to 4 k) can be connected to the analogue temperature input. The power supply for the digital sensor is integrated in the unit.The LCD graphic display allows the input signals to be shown as digits or as a bar graph. The display of the parameters in plain text makes operation easy to understand and safe.With two optional relay change-over contacts, both simple switching or alarm functions and sophisticated control tasks with P, PI, PD and PID behaviour can be realised. On request, the unit can also be supplied with two freely parameterisable and scalable analogue outputs (0 to 10 V, or 0(4) to 20 mA).Special featuresDisplay: mg/l, ppm, % SAT, %, ‰, g/l, ppb, µg/l, NTU, FNU, etc.Special displays are also possible with the setup programmeLarge LCD graphic display with backlightingDisplay representation selectable: large digits, bargraph or trend displayIntegrated calibration routines:depending on the sensor: zero point, full scale and 2-pointCalibration logbookProtection class IP67 for surface mountingProtection class IP65 for control cabinet mountingOperator languages (switchable): German, English, Frenchthrough setup program (option): convenient programming, system documentation, reloading of additional operating languages Frequently Asked Questions What exactly can the JUMO AQUIS RS do? The device displays readings from digital sensors and can monitor and control them at the same time. Which sensors is the device compatible with? It works with digital sensors that support the Modbus protocol. Where can I use the device? For example, in water treatment, industrial plants, or anywhere where measured values need to be monitored. Can I transmit the measured values to other devices? Yes, values can be transmitted to other systems via the analogue output (0–20 mA, 4–20 mA or 0–10 V). Can I see the measured values directly on the device? Yes, the current values are displayed directly on the integrated display. Why is this device a good choice for my system? It combines display, monitoring and signal transmission in a single compact device, thereby simplifying process control.
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Capacity measurement ion exchanger cartridgeOur Neomeris N-FLASH10 conductivity meter in a T-piece with 3/8 inch connection is a conductivity measuring instrument that is used to monitor the electrical conductivity of water after flowing through the ion exchanger cartridge. The measuring instrument including the integrated measuring cell is battery operated and permanently installed in the T-piece. If the measured electrical conductivity is below the limit value of 10µS/cm, the green LED flashes; if it is above, the red LED flashes, indicating that a cartridge or resin change is required. Due to the T-piece used, the measuring device can also be integrated very easily and is optimally installed in the liquid flow for a stable measurement. Measuring principle: The measuring cell generates an electrical signal that is proportional to the conductivity of the liquid. This signal is processed in the device and the LED is controlled via the programming stored in the device. Application: Conductivity meters are often used in water treatment plants in the process industry.Technical data:Screw-in thread: 3/8"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <20μS/cm LED yellow 20-50μS/cm LED red >50μS/cm Frequently Asked Questions Why do I need a conductivity meter in my system? It allows you to quickly see how clean your water is and whether, for example, a filter or water treatment system is working properly. For which systems is this meter particularly well suited? It is frequently used in water treatment and osmosis systems, or in technical installations for water monitoring. Can I simply screw the measuring cell into my water pipe? Yes, it is screwed directly into a 3/4″ connection and can usually be easily integrated. How accurately does the device indicate water quality? It measures the conductivity of the water and thus quickly indicates changes in water quality. Is the device also suitable for very pure water? Yes, the measuring range up to 100 µS is specifically designed for very pure or treated water. Do I need to maintain or clean the measuring device regularly? As a rule, occasional inspection and cleaning of the measuring cell is sufficient.
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <20μS/cm LED yellow 20-50μS/cm LED red >50μS/cm Frequently Asked Questions Why do I need a conductivity meter in my system? It allows you to quickly see how clean your water is and whether, for example, a filter or water treatment system is working properly. For which systems is this meter particularly well suited? It is frequently used in water treatment and osmosis systems, or in technical installations for water monitoring. Can I simply screw the measuring cell into my water pipe? Yes, it is screwed directly into a 3/4″ connection and can usually be easily integrated. How accurately does the device indicate water quality? It measures the conductivity of the water and thus quickly indicates changes in water quality. Is the device also suitable for very pure water? Yes, the measuring range up to 100 µS is specifically designed for very pure or treated water. Do I need to maintain or clean the measuring device regularly? As a rule, occasional inspection and cleaning of the measuring cell is sufficient.
Features of the N-FLASH50 Device The N-FLASH50 is a compact, battery-powered conductivity meter designed to monitor conductivities in the range of 0 to 50 µS/cm. Thanks to its handy design, it is ideal for mobile use and short-term measurements directly on site. The clear LED display allows quick evaluation of measurement results without additional analysis devices. Mobile Conductivity Meter for Quick Checks Three integrated LEDs clearly indicate the current measurement status: green signals a safe range, yellow indicates threshold levels, and red warns of excessively high conductivity. The integrated 3/4"-threaded measurement cell allows direct installation in pipelines and ensures uncomplicated measurement during ongoing operations. Battery operation provides maximum flexibility, independent of external power supply. Why Conductivity Is Measured in Water Treatment Conductivity indicates how many dissolved salts and ions are present in water. It is therefore an important indicator for assessing water quality. In water treatment, it is used to monitor desalination and treatment processes and to detect deviations from target values early. Excessively high conductivity values can indicate exhausted filters, defective membranes, or contamination. Regular measurement protects equipment, ensures process quality, and helps comply with regulatory limits. Frequently asked questions Are there other measuring ranges available? The standard measuring ranges can be found in the product's drop-down menu. If the measuring range you require is not listed, don't worry. Simply let us know and we will check whether we can configure the item to suit your needs. Are there other thread sizes available? If the desired connection thread is not listed, that's no problem. Let us know your desired thread and we will check whether we can configure the item for you with the appropriate thread. For enquiries, please contact our service department on +49 (0) 5121 7609 99 or at vertrieb@heylneomeris.de Is it possible to label the conductivity meter with my own company logo so that we can sell it ourselves in future? That's no problem. Please provide us with more detailed information so that we can process your enquiry. Please note that the price will change due to the increased effort involved and that the minimum purchase quantity for product labelling is 100 units.