JUMO AQUIS 500 pH - transmitter/controller in surface-mounted housing, 2x 0(4)-20mA / 0(2) to 10V output + 2x relay output, AC 20 to 30V power supply
€1,402.89*
Please log in to receive your conditions.
Available in 28 days, delivery time 1-2 days
(Login for quotation) The entered number of pieces will be taken into account when creating the offer.
Product information "JUMO AQUIS 500 pH - transmitter/controller in surface-mounted housing, 2x 0(4)-20mA / 0(2) to 10V output + 2x relay output, AC 20 to 30V power supply"
Version 2: stock version: type 202560/20-888-000-310-000-23/000 ; part-no. 00480050
- direct switching option for pH value, redox voltage or NH3 (ammonia) concentration
- Automatic temperature compensation
- Large LC graphic display with backlighting
- Display selectable: large digits, bar graph or tendency display
- Solderless connection technology - Calibration options depending on measurand one/two/three-point calibration
- calibration logbook
- Impedance measurement can be activated for pH measurement
- Asymmetrical and symmetrical connection of pH sensors
- Possibility of connecting pH ISFET sensors through integrated output for sensor power supply
- Protection class IP67 for surface mounting, protection class IP65 for control cabinet mounting
- User languages switchable German, English, French; further languages can be loaded via setup program
- Through setup program: convenient programming, system documentation, reloading of further user languages
JUMO AQUIS 500 – Modular Measuring and Control Systems for Precise Water Analysis
The JUMO AQUIS 500 series includes a range of powerful, modular measuring and control devices for monitoring analytical water parameters such as pH, redox, conductivity, temperature, and more. Each model (e.g., AQUIS 500 pH, CR) is tailored to a specific sensor type or measurement range, making the series ideal for use in water treatment, environmental technology, process engineering, and industrial process monitoring.
At HeylNeomeris, the AQUIS 500 series provides reliable solutions for stationary applications that demand high measurement accuracy, flexible system integration, and user-friendly operation.
Advantages of the JUMO AQUIS 500 Series:
• The series offers tailored solutions for various measurement tasks – from pH to conductivity
• Modular design and compatibility allow for easy integration into existing systems
• Digital interfaces (e.g., 0/4–20 mA, relay outputs) enable seamless automation
• The devices deliver stable and precise measurements, even during continuous operation
• A clear display and intuitive menu navigation simplify installation and maintenance
• With IP65 protection and a robust design, they are well suited for industrial environments
Dimensions
Height | 14 cm |
---|---|
Length | 34,5 cm |
Width | 23,5 cm |
Weight
Weight | 1,4 kg |
---|
Other attributes
Country of origin | DE |
---|---|
Customs tariff number | 90278930 |
Downloads:
Selection Matrix:
JUMO AQUIS 500 pH |
Basic type |
Output 1 |
Output 2 |
Output 3 |
Output 4 |
Power supply |
Extra codes |
||
Panel mounting |
Surface-mounted housing |
analogue, 0(4) to 20 mA ref. 0(2) to 10V |
analogue, 0(4) to 20 mA ref. 0(2) to 10V |
Relay with switch contakt |
Relay with switch contakt |
AC 110 to 240 V |
AC/DC 20 to 30 V |
||
Variant 1 |
• |
• |
• |
• |
• |
• |
none |
||
Variant 2 |
• |
• |
• |
• |
none |
||||
Variant 3 |
• |
• |
• |
none |
|||||
Variant 4 |
• |
• |
• |
• |
• |
• |
none |
||
Variant 5 |
• |
• |
• |
• |
none |
||||
Variant 6 |
• |
• |
• |
• |
• |
• |
none |
||
individual |
according to type sheet, please inform us of your request |
Technical Specifications:
Inputs |
|||||||
Main input |
Measuring range/Regulation range |
Accuracy |
Temperature impact |
||||
pH value |
-1 to +15 pH |
£ 0,3 % |
0,2 %/10 K |
||||
ORP voltage |
-1500 to +1500 mV |
£ 0,3 % |
0,2 %/10 K |
||||
NH3 (Ammonia) |
0 to 9999 ppm |
£ 0,3 % |
0,2 %/10 K |
||||
Side input |
|||||||
Temperature Pt100/1000 (automatic detection) |
-50 to +250 °Ca |
£ 0,5 °C |
0,05 %/10 K |
||||
Temperature NTC/PTC |
max. 4 kW Input via table with 20 value pairs |
£ 0,3 %b |
0,05 %/10 K |
||||
a Switchable to °F. b Depending on the support points. |
|||||||
Temperature compensation |
|||||||
Measured variable |
Compensation |
Rangea |
|||||
pH value |
yes |
-30 to +150 °C (from software version 212.11.02) |
|||||
-10 to +150 °C (until software version 212.11.01) |
|||||||
ORP voltage |
no |
n/a |
|||||
NH3 (Ammonia) |
yes |
-20 to +50 °C |
|||||
pH antimony |
yes |
-10 to +80 °C |
|||||
a Observe the operating temperature range of the sensor! |
|||||||
Measuring circuit monitoring |
|||||||
Inputs |
Underrange / Overrange |
Short circuit |
Wire break |
||||
pH value |
yes |
yesa |
yesa |
||||
NH3 (Ammonia) |
yes |
no |
no |
||||
pH antimony |
yes |
no |
no |
||||
Temperature |
yes |
yes |
yes |
||||
a During pH measurement, the sensor can be monitored for short-circuits and line breaks by activating impedance measurement. |
|||||||
Impedance measurement |
|||||||
The impedance measurement can be activated optionally. Since it is dependent on some boundary parameters, the following points must be observed:
It is not permissible to use an impedance converter in the measuring circuit!
It is therefore recommended to activate the measurement in liquids from a minimum conductivity of approx. 100 µS/cm. |
|||||||
Binary Input |
|||||||
Activation |
by potential-free contact |
||||||
Function |
Key lock HOLD Alarm suppression |
||||||
Regulator |
|||||||
Regulator type |
Limit comparators, limit controllers, pulse width controllers, pulse frequency controllers, three-point stepping controllers, continuous controllers |
||||||
Regulator structure |
P/PI/PD/PID |
||||||
A/D-Converter |
Dynamic resolution up to 14 bit |
||||||
Sampling time |
500 ms |
||||||
Analoguee Outputs (max. 2) |
|||||||
Output type |
Signal range |
Accuracy |
Temperature impact |
permissible load resistance |
|||
Power signal |
0/4 to 20 mA |
£ 0,25 % |
0,08 %/10 K |
£ 500 W |
|||
Voltage signal |
0 to 10 V |
£ 0,25 % |
0,08 %/10 K |
£ 500 W |
|||
The analogue outputs behave according to the recommendation of NAMUR NE43. They are galvanically isolated, AC 30 V / DC 50 V. |
|||||||
Switching outputs (maximum two changeover contacts) |
|||||||
Nominal load |
3 A/AC 250 V (resistive load) |
||||||
Contact lifetime |
>2 × 105 switches at nominal load |
||||||
Electrical Specifications: |
|||||||
Power supply |
AC 110 to 240 V; -15/+10 %; 48 to 63 Hz AC/DC 20 to 30 V; 48 to 63 Hz DC12 to 24 V; +/-15 % (Connection only permitted to SELV/PELV circuits) |
||||||
Power consumption |
approx. 14 VA |
||||||
Electric safety |
DIN EN 61010, Part 1 Overvoltage category IIIa, Pollution level 2 |
||||||
Data backup |
EEPROM |
||||||
Electrical connection |
Screw terminals Wire cross-section max. 2.5 mm2 (Power supply, relay outputs, sensor inputs) Wire cross-section max. 1.5 mm2 (analogue outputs; supply ISFET) |
||||||
a Not valid for protective extra-low voltage of the power supply variant DC 12 to 24 V. |
|||||||
Housing |
|||||||
Material |
ABS |
||||||
Wire feed |
Wire glands, max. 3 × M16 and 2 × M12) |
||||||
Special Feature |
Venting element to prevent condensation |
||||||
Environmental temperature range (Accuracy specifications are adhered to in this range) |
-10 to +50°C |
||||||
Operating temperature range (Function of the unit is given) |
-15 to +65°C |
||||||
Storage temperature range |
-30 to +70°C |
||||||
Climate resistance |
rel. Humidity £ 90 % annual average without condensation (based on DIN EN 60721 3-3 3K3) |
||||||
Protection classes according to EN 60529 |
Surface-mounted housing: IP67 Panel mounting: front IP65, rear IP20 |
||||||
Swinging proof |
according to DIN EN 60068-2-6 |
||||||
Weight |
Surface-mounted housing: approx. 900 g Control cabinet installation: approx. 480 g |
||||||
Dimensions |
See type sheet |
||||||
Approvals/Mark of conformity |
|||||||
Mark of conformity |
Test centre |
Certificates/Test numbers |
Test basis |
applies to |
|||
c UL us |
Underwriters Laboratories |
E 201387 |
UL 61010-1 |
all variants |